Датчики положения, давления/вакуума, расхода

тип:
Бренд:
Показывать:

Датчик расхода SFAB-1000U-WQ10-2SA-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-10
Ambient temp0 - 50 °C
Analogue output4 - 20 mA
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value1000 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value1000 l/min
Flow measurement range initial value10 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. load resistance, current output500 Ohm
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Nominal temperature23 °C
Operating mediumAir quality class 5:4:3 as per DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value20 mA
Output characteristic curve initial value4 mA
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-1000U-WQ10-2SV-M12..

Датчик расхода

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-10
Ambient temp0 - 50 °C
Analogue output0 - 10 V
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value1000 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value1000 l/min
Flow measurement range initial value10 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Min. load resistance, voltage output10 kOhm
Nominal temperature23 °C
Operating mediumAir quality class 5:4:3 as per DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value10 V
Output characteristic curve initial value0 V
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-10U-HQ6-2SA-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-6
Ambient temp0 - 50 °C
Analogue output4 - 20 mA
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value10 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value10 l/min
Flow measurement range initial value0.1 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. load resistance, current output500 Ohm
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Nominal temperature23 °C
Operating mediumAir quality class 3:4:1 to DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value20 mA
Output characteristic curve initial value4 mA
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-10U-HQ6-2SV-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-6
Ambient temp0 - 50 °C
Analogue output0 - 10 V
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value10 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value10 l/min
Flow measurement range initial value0.1 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Min. load resistance, voltage output10 kOhm
Nominal temperature23 °C
Operating mediumAir quality class 3:4:1 to DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value10 V
Output characteristic curve initial value0 V
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-10U-WQ6-2SA-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-6
Ambient temp0 - 50 °C
Analogue output4 - 20 mA
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value10 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value10 l/min
Flow measurement range initial value0.1 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. load resistance, current output500 Ohm
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Nominal temperature23 °C
Operating mediumAir quality class 3:4:1 to DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value20 mA
Output characteristic curve initial value4 mA
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-10U-WQ6-2SV-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-6
Ambient temp0 - 50 °C
Analogue output0 - 10 V
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value10 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value10 l/min
Flow measurement range initial value0.1 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Min. load resistance, voltage output10 kOhm
Nominal temperature23 °C
Operating mediumAir quality class 3:4:1 to DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value10 V
Output characteristic curve initial value0 V
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-200U-HQ10-2SA-M12..

Датчик расхода

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-10
Ambient temp0 - 50 °C
Analogue output4 - 20 mA
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value200 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value200 l/min
Flow measurement range initial value2 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. load resistance, current output500 Ohm
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Nominal temperature23 °C
Operating mediumAir quality class 5:4:3 as per DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value20 mA
Output characteristic curve initial value4 mA
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-200U-HQ10-2SV-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-10
Ambient temp0 - 50 °C
Analogue output0 - 10 V
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value200 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value200 l/min
Flow measurement range initial value2 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Min. load resistance, voltage output10 kOhm
Nominal temperature23 °C
Operating mediumAir quality class 5:4:3 as per DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value10 V
Output characteristic curve initial value0 V
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-200U-HQ8-2SA-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-8
Ambient temp0 - 50 °C
Analogue output4 - 20 mA
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value200 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value200 l/min
Flow measurement range initial value2 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. load resistance, current output500 Ohm
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Nominal temperature23 °C
Operating mediumAir quality class 5:4:3 as per DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value20 mA
Output characteristic curve initial value4 mA
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-200U-HQ8-2SV-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-8
Ambient temp0 - 50 °C
Analogue output0 - 10 V
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value200 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value200 l/min
Flow measurement range initial value2 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Min. load resistance, voltage output10 kOhm
Nominal temperature23 °C
Operating mediumAir quality class 5:4:3 as per DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value10 V
Output characteristic curve initial value0 V
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-200U-WQ10-2SA-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-10
Ambient temp0 - 50 °C
Analogue output4 - 20 mA
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value200 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value200 l/min
Flow measurement range initial value2 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. load resistance, current output500 Ohm
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Nominal temperature23 °C
Operating mediumAir quality class 5:4:3 as per DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value20 mA
Output characteristic curve initial value4 mA
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-200U-WQ10-2SV-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-10
Ambient temp0 - 50 °C
Analogue output0 - 10 V
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value200 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value200 l/min
Flow measurement range initial value2 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Min. load resistance, voltage output10 kOhm
Nominal temperature23 °C
Operating mediumAir quality class 5:4:3 as per DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value10 V
Output characteristic curve initial value0 V
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-200U-WQ8-2SA-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-8
Ambient temp0 - 50 °C
Analogue output4 - 20 mA
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value200 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value200 l/min
Flow measurement range initial value2 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. load resistance, current output500 Ohm
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Nominal temperature23 °C
Operating mediumAir quality class 5:4:3 as per DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value20 mA
Output characteristic curve initial value4 mA
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-200U-WQ8-2SV-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-8
Ambient temp0 - 50 °C
Analogue output0 - 10 V
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value200 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value200 l/min
Flow measurement range initial value2 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Min. load resistance, voltage output10 kOhm
Nominal temperature23 °C
Operating mediumAir quality class 5:4:3 as per DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value10 V
Output characteristic curve initial value0 V
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-50U-HQ6-2SA-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-6
Ambient temp0 - 50 °C
Analogue output4 - 20 mA
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value50 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value50 l/min
Flow measurement range initial value0.5 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. load resistance, current output500 Ohm
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Nominal temperature23 °C
Operating mediumAir quality class 3:4:1 to DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value20 mA
Output characteristic curve initial value4 mA
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-50U-HQ6-2SV-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-6
Ambient temp0 - 50 °C
Analogue output0 - 10 V
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value50 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value50 l/min
Flow measurement range initial value0.5 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Min. load resistance, voltage output10 kOhm
Nominal temperature23 °C
Operating mediumAir quality class 3:4:1 to DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value10 V
Output characteristic curve initial value0 V
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-50U-WQ6-2SA-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-6
Ambient temp0 - 50 °C
Analogue output4 - 20 mA
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value50 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value50 l/min
Flow measurement range initial value0.5 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. load resistance, current output500 Ohm
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Nominal temperature23 °C
Operating mediumAir quality class 3:4:1 to DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value20 mA
Output characteristic curve initial value4 mA
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-50U-WQ6-2SV-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-6
Ambient temp0 - 50 °C
Analogue output0 - 10 V
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value50 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value50 l/min
Flow measurement range initial value0.5 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Min. load resistance, voltage output10 kOhm
Nominal temperature23 °C
Operating mediumAir quality class 3:4:1 to DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value10 V
Output characteristic curve initial value0 V
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/h
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-600U-HQ10-2SA-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-10
Ambient temp0 - 50 °C
Analogue output4 - 20 mA
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value600 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value600 l/min
Flow measurement range initial value6 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. load resistance, current output500 Ohm
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Nominal temperature23 °C
Operating mediumAir quality class 5:4:3 as per DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value20 mA
Output characteristic curve initial value4 mA
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo

Датчик расхода SFAB-600U-HQ10-2SV-M12..

Датчик расхода 

PropertyNo
Product TypeFesto Flow sensors
Short type codeSFAB
Electrical Connect5-pin
Electrical ConnectM12 x 1
Electrical ConnectPlug straight
MountingOptional
MountingWith through hole
MountingWith top-hat rail
MountingWith wall/surface fixing
Pneumatic connectionQS-10
Ambient temp0 - 50 °C
Analogue output0 - 10 V
Assembly positionAny
ATEX category DustII 3D
ATEX category GasII 3G
Authorisationc UL us - Recognized (OL)
AuthorisationC-Tick
CE mark (see declaration of conformity)to EU directive explosion protection (ATEX)
CE mark (see declaration of conformity)to EU directive for EMC
Characteristic curve for flow rate final value600 l/min
Characteristic curve for flow rate initial value0 l/min
Connector pin assignments per standardEN 60947-5-2
Corrosion resistance classification CRC2
Direction of flowP1 -> P2
Direction of flowUnidirectional
Explosion ignition protection type DustEx tD A22 IP54 T80°C
Explosion ignition protection type GasEx nA II T5 X
Explosion protectionZone 2 (ATEX)
Explosion protectionZone 22 (ATEX)
Explosion-proof ambient temperature0°C <= Ta <= +50°C
Flow measurement range final value600 l/min
Flow measurement range initial value6 l/min
Materials information, housingPA-reinforced
Materials noteConforms to RoHS
Max. output current<= 100 mA
Measured variableConsumption
Measured variableFlow rate
Measuring principleThermal
Medium temperature0 - 50 °C
Min. load resistance, voltage output10 kOhm
Nominal temperature23 °C
Operating mediumAir quality class 5:4:3 as per DIN ISO 8573-1
Operating mediumNitrogen
Operating Pressure0 - 10 bar
Operating voltage range DC15 - 30 V
Output characteristic curve final value10 V
Output characteristic curve initial value0 V
Polarity protectedfor all electrical connections
Precision margin in ± %FS3 %FS
Precision zero point in ± %FS0.3 %FS
Pressure drop< 100 mbar
Product weight600 g
Protection classIP65
Repetition accuracy margin in ± %FS0.8 %FS
Repetition accuracy zero point in ± %FS0.2 %FS
Short circuit strengthYes
Switch output2 x PNP or 2 x NPN switchable
Switching element functionNormally closed contact
Switching element functionNormally open contact
Switching functionThreshold value comparator
Switching functionWindow comparator
Type of displayIlluminated LCD blue
Unit(s) that can be displayedl
Unit(s) that can be displayedl/min
Unit(s) that can be displayedm3
Unit(s) that can be displayedscf
Unit(s) that can be displayedscfm

 

Производитель: Festo
Датчики положения, давления/вакуума, расхода